Trenton TMP medium profile evaporators

TMP is Trenton Refrigeration's medium profile unit cooler line for walk-in coolers and freezers. Models span medium temperature (10 to 35 F evaporator temperature) and low temperature (-40 to 0 F) applications, with electric, air, hot gas, and reverse cycle defrost options, and EC fan motors with SmartSpeed technology.

Search TMP models
Trenton Refrigeration TMP
Trenton TMP unit cooler

Image: Trenton Refrigeration

Nomenclature

TMP347LET4E

Family

Medium profile evaporator

Fans

1 to 4

Nominal capacity x 1000

13 to 95 MBH (x 1000 BTU/h)

Temperature class

  • MMedium Temp 6 FPI (10°F to 35°F Evap Temp)
  • LLow Temp 6 FPI (-40°F to 0°F Evap Temp)
  • VLow Temp 4 FPI (-40°F to 0°F Evap Temp)

Generation

  • EA2L and A1 refrigerant compatible, AWEF Compliant

Voltage

  • S4460/1/60
  • T3208-230/3/60
  • T4460/3/60
  • S2208-230/1/60*

Defrost

  • AAir
  • EElectric
  • T3 pipe hot gas w/ electric heater pan
  • H3 pipe hot gas w/ hot gas loop pan
  • GReverse Cycle w/ Electric Heater Pan
  • RReverse Cycle w/ Hot Gas Loop Pan

marks an option the other bulletin lists differently or not at all. * marks one this bulletin prints in its tables but leaves out of its legend.

Documented discrepancies

The 5 places Trenton Refrigeration's TMP documents disagree with each other, with the value on each side, are a free member benefit. Leave an email to be told when member accounts go live.

Documentation history (2025 to 2026)

Generations D and E

The line is documented in two active generations. Generation D covers A1 refrigerants (R-404A, R-448A, R-449A, R-507, and related blends) and transcritical CO2, and is AWEF compliant. Generation E is the A2L generation: it adds the mildly flammable low-GWP refrigerants R-454A, R-454C, and R-455A that new refrigeration equipment is moving to in the U.S. low-GWP transition.

Generation E equipment carries the A2L safety package alongside the refrigerant change. The GEN E bulletin lists an A2L Refrigerant Detection System (RDS), a leak mitigation system built on safety shut off valves (SSOV) and check shut off valves (CSOV), and the ESP+ evaporator control as factory options. It also narrows the SmartSpeed EC motor statement to 230 V and 460 V models, a caveat the combined bulletin does not carry.

CO2 sits only on the generation D side of the documentation. The combined bulletin defines three CO2 application classes (C, D, and F) and two 575 V CO2 voltage codes (S5 and T5); the GEN E bulletin does not mention CO2 at all. Whether CO2 models continue past generation D is not something the current documentation answers.

TMP models

457 documented configurations, 13 to 95 MBH (x 1000 BTU/h).

Search TMP models

Sources

  1. [1]

    Source documents

    Direct links to the manufacturer documents behind this page are a free member benefit. Leave an email to be told when member accounts and source access go live.

  2. [2]

    Source documents

    Direct links to the manufacturer documents behind this page are a free member benefit. Leave an email to be told when member accounts and source access go live.

Updated