Trenton Refrigeration · TTM · Two-Way Evaporators
TTM318MA-S1D
Trenton Refrigeration TTM two-way evaporator.
62 extracted specifications, each traceable to its source document and page.
Specifications
| Specification | Value | Conditions | Source |
|---|---|---|---|
| fan qty | 3 count | p.3 | |
| 3 count | p.3 | ||
| 3 count | p.14 | ||
| 3 count | p.15 | ||
| 3 count | p.4 | ||
| 3 count | p.22 | ||
| capacity | 18300 btu_h | evap temp f: 25 | p.3 |
| 18100 btu_h | evap temp f: 15 | p.3 | |
| 17900 btu_h | evap temp f: 10 | p.3 | |
| 14800 btu_h | evap temp f: 25 | p.3 | |
| 14700 btu_h | evap temp f: 15 | p.3 | |
| 14500 btu_h | evap temp f: 10 | p.3 | |
| airflow | 3030 cfm | p.3 | |
| 1430 l_s | p.3 | ||
| 3030 cfm | p.3 | ||
| 1430 l_s | p.3 | ||
| refrigerant charge | 3.4 lb | p.3 | |
| 1.5 kg | p.3 | ||
| 3.1 lb | p.3 | ||
| 1.4 kg | p.3 | ||
| awef rating | 9 ratio | refrigerant: R404A/R507 | p.14 |
| 9 ratio | refrigerant: R407A | p.14 | |
| 9 ratio | refrigerant: R448A/R449A | p.14 | |
| suction od | 0.875 inches | p.14 | |
| 22 mm | p.14 | ||
| distributor inlet | 0.5 inches | p.14 | |
| 13 mm | p.14 | ||
| hot gas connection | 0.5 inches | p.14 | |
| 13 mm | p.14 | ||
| shipping weight | 150 lb | p.14 | |
| 68 kg | p.14 | ||
| dimension A | 93.5 inches | p.15 | |
| 2375 mm | p.15 | ||
| 93.5 inches | p.22 | ||
| 2375 mm | p.22 | ||
| dimension unparsed | 81 | p.15 | |
| 2057 40.5 | p.15 | ||
| 1029 - - | p.15 | ||
| 81 | p.22 | ||
| 2057 40.5 | p.22 | ||
| 1029 - - | p.22 | ||
| dimension E | - inches | p.15 | |
| - mm | p.15 | ||
| - inches | p.22 | ||
| - mm | p.22 | ||
| distributor nozzle | L1-1/2 part_id | p.17 | |
| L1-1/2 part_id | p.17 | ||
| L1-1/2 part_id | p.18 | ||
| L1-1/2 part_id | p.18 | ||
| txv model | SBQVE-B-C part_number | p.17 | |
| SBQSE-B-C part_number | p.17 | ||
| E2V18 part_number | p.18 | ||
| E2V18 part_number | p.18 | ||
| solenoid valve | 5 part_number | p.18 | |
| 5 part_number | p.18 | ||
| motor fla | 4.5 amps | p.4 | |
| total watts | 156 watts | p.4 | |
| mca | 4.9 amps | p.4 | |
| fan motors standard ec motors mop a | 15 | p.4 | |
| voltage | 115 V | p.? | |
| phase | 1 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: TTM_1109291 · extraction with per-cell provenance · verify before purchase. · variants from distributor API snapshot
Orderable variants (1)
| Variant | Voltage | Availability |
|---|---|---|
| TTM318MA-S1D | 115/1/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 18 |
| defrost | A |
| fan count | 3 |
| generation suffix | D |
| temp class | M |
| voltage | S1 |
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KTM318MA-S1D | shared catalog stem ✓ |
| Bally | BTM318MA-S1D | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TTM318MA-S1D?
TTM318MA-S1D has a rated capacity of 18300 btu_h. See the specifications table for rating conditions.
What voltage does TTM318MA-S1D require?
TTM318MA-S1D runs on 115 V supply power.
Related models in TTM
Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.