TMP470LE-S4D

Trenton Refrigeration TMP medium profile evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
fan qty4 countp.4
capacity74500 btu_hp.4
72400 btu_hp.4
70300 btu_hp.4
64700 btu_hp.4
59800 btu_hp.4
60600 btu_hp.4
58900 btu_hp.4
57200 btu_hp.4
52600 btu_hp.4
48600 btu_hp.4
74500 btu_hp.4
72400 btu_hp.4
70300 btu_hp.4
64700 btu_hp.4
59800 btu_hp.4
airflow11490 cfmp.4
5420 l_sp.4
11490 cfmp.4
5420 l_sp.4
11490 cfmp.4
5420 l_sp.4
refrigerant charge9 lbp.4
4.1 kgp.4
8.4 lbp.4
3.8 kgp.4
8.1 lbp.4
3.7 kgp.4
8.6 lbp.4
3.9 kgp.4
awef rating4.15 ratiop.33
4.15 ratiop.33
4.15 ratiop.33
4.15 ratiop.33
4.15 ratiop.33
4.15 ratiop.33
hot gas connection4 inchessources differTMP p.35
1 1/8 inchessources differTMP p.35
1 3/8 inchessources differTMP p.35
suction od2 1/8 inchesp.35
distributor inlet1 5/8 inchessources differTMP p.35
1 3/8 inchessources differTMP p.35
shipping weight443 lbp.36
201 kgp.36
motor hp0.3333333333333333 hpp.8
motor fla6.4 ampsp.8
total watts840 wattssources differTMP p.8
10600 wattssources differTMP p.8
mca15 ampssources differTMP p.8
29 ampssources differTMP p.8
28.6 ampssources differTMP p.11
mop15 ampsp.8
total amps23 ampsp.8
defrost heaters mop a30p.8
fpi4p.11
esp circuit 460 1 60 mop a30p.11
voltage 208 230 1 60460/1/60p.66
1 x evaporator defrost kit dfk 10DFK-10p.66
1 x evaporator fuse package fp 015FP-102p.66
2 x evaporator defrost kit dfk 12DFK-12p.66
2 x evaporator fuse package fp 116FP-097p.66
voltage460 Vp.?
phase1 php.?
frequency60 Hzp.?

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TMP_1109295, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.

Orderable variants (1)

VariantVoltageAvailability
TMP470LE-S4D460/1/60Check availability

Nomenclature

Position / meaningValue
capacity code70
capacity mbh70
defrostE
fan count4
generation suffixD
temp classL
voltageS4

Parts

7 factory parts for this unit: 7from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.

PartPart numberQtyListAvailability
Distributor nozzleA12--Check availability
Electronic expansion valveE3V45order as E3V45BWRC1--Check availability
Safety check valveCSOV17order as CSOV-17S--Check availability
Safety shutoff solenoidSSOV19--Check availability
Solenoid valveB10order as B10S2-5/8--Check availability
TXVEBSSE-10-ZP--Check availability
TXVEBSVE-15-ZPorder as EBSVE-15-ZP40--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

BrandEquivalent modelBasis
KeepRiteKMP470LE-S4Dshared catalog stem
BallyBMP470LE-S4Dshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of TMP470LE-S4D?

TMP470LE-S4D has a rated capacity of 74500 btu_h. See the specifications table for rating conditions.

What voltage does TMP470LE-S4D require?

TMP470LE-S4D runs on 460 V supply power.

Related models in TMP

Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.