TMP349VE-S4E
Trenton Refrigeration TMP evaporator.
Specifications
Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.
| Specification | Value | Conditions | Source |
|---|---|---|---|
| fan qty | 3 count | TMP + TMP-GEN-E p.5 ✓ | |
| capacity | 51700 btu_h | evap temp f: 0; refrigerant: R407A/R448A | p.5 |
| 50300 btu_h | evap temp f: 10; refrigerant: R407A/R448A | p.5 | |
| 48800 btu_h | evap temp f: 20; refrigerant: R407A/R448A | p.5 | |
| 44900 btu_h | evap temp f: 30; refrigerant: R407A/R448A | p.5 | |
| 41500 btu_h | evap temp f: 40; refrigerant: R407A/R448A | p.5 | |
| 42000 btu_h | evap temp f: 0; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 40800 btu_h | evap temp f: 10; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 39600 btu_h | evap temp f: 20; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 36400 btu_h | evap temp f: 30; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 33700 btu_h | evap temp f: 40; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 51700 btu_h | evap temp f: 0; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 50300 btu_h | evap temp f: 10; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 48800 btu_h | evap temp f: 20; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 44900 btu_h | evap temp f: 30; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 41500 btu_h | evap temp f: 40; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 51700 btu_h | evap temp f: 0; refrigerant: R407A/R448A/R449A | p.6 | |
| 50300 btu_h | evap temp f: 10; refrigerant: R407A/R448A/R449A | p.6 | |
| 48800 btu_h | evap temp f: 20; refrigerant: R407A/R448A/R449A | p.6 | |
| 44900 btu_h | evap temp f: 30; refrigerant: R407A/R448A/R449A | p.6 | |
| 41500 btu_h | evap temp f: 40; refrigerant: R407A/R448A/R449A | p.6 | |
| airflow | 9100 cfm | refrigerant: R407A/R448A | p.5 |
| 4290 l_s | refrigerant: R407A/R448A | p.5 | |
| 9100 cfm | refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 4290 l_s | refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 9100 cfm | refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 4290 l_s | refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 9100 cfm | refrigerant: R407A/R448A/R449A | p.6 | |
| 4290 l_s | refrigerant: R407A/R448A/R449A | p.6 | |
| refrigerant charge | 7.5 lb | refrigerant: R407A | TMP + TMP-GEN-E p.5 ✓ |
| 3.4 kg | refrigerant: R407A | TMP + TMP-GEN-E p.5 ✓ | |
| 7 lbsources differ | refrigerant: R404A | TMP p.5 | |
| 13.8 lbsources differ | refrigerant: R404A | TMP-GEN-E p.7 | |
| 3.2 kgsources differ | refrigerant: R404A | TMP p.5 | |
| 6.3 kgsources differ | refrigerant: R404A | TMP-GEN-E p.7 | |
| 6.7 lbsources differ | refrigerant: R454A/R454C/R455A | TMP p.5 | |
| 6.8 lbsources differ | refrigerant: R454A/R454C/R455A | TMP-GEN-E p.4 | |
| 3 kgsources differ | refrigerant: R454A/R454C/R455A | TMP p.5 | |
| 3.1 kgsources differ | refrigerant: R454A/R454C/R455A | TMP-GEN-E p.4 | |
| 7.2 lb | refrigerant: R448A | p.5 | |
| 3.3 kg | refrigerant: R448A | p.5 | |
| 7.2 lb | refrigerant: R448A/R449A | p.6 | |
| 3.3 kg | refrigerant: R448A/R449A | p.6 | |
| awef rating | 4.15 ratio | refrigerant: R404A/R507 | p.33 ✓ |
| 4.15 ratio | refrigerant: R407A | p.33 | |
| 4.15 ratio | refrigerant: R448A/R449A | p.33 | |
| 4.15 ratio | refrigerant: R454A | p.33 | |
| 4.15 ratio | refrigerant: R454C | p.33 | |
| 4.15 ratio | refrigerant: R455A | p.33 | |
| 4.15 ratio | fpi: 4 | p.31 | |
| suction od | 1 5/8 inches | TMP + TMP-GEN-E p.35 ✓ | |
| distributor inlet | 1 3/8 inchessources differ | TMP p.35 | |
| 1 1/8 inchessources differ | TMP p.35 | ||
| 1 3/8 inchessources differ | TMP-GEN-E p.34 | ||
| 1 1/8 inchessources differ | TMP-GEN-E p.33 | ||
| hot gas connection | 0.875 inchessources differ | TMP p.35 | |
| 1 1/8 inchessources differ | TMP p.35 | ||
| shipping weight | 362 lb | TMP + TMP-GEN-E p.36 ✓ | |
| 164 kg | TMP + TMP-GEN-E p.36 ✓ | ||
| mca | 24.6 ampssources differ | TMP p.11 | |
| 15 ampssources differ | TMP-GEN-E p.12 | ||
| 25 ampssources differ | TMP-GEN-E p.12 | ||
| esp circuit 460 1 60 mop a | 25 | TMP + TMP-GEN-E p.11 ✓ | |
| voltage | 460 V | TMP + TMP-GEN-E p.? ✓ | |
| phase | 1 ph | TMP + TMP-GEN-E p.? ✓ | |
| frequency | 60 Hz | TMP + TMP-GEN-E p.? ✓ | |
| side port connection | 0.875 inches | p.34 | |
| drain pan loop conn od sweat | 1 1/8 | p.34 | |
| r454a sporlan sbqte b zp | EBSTE-11-ZP | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.37 |
| r448a r449a r407a r407c r454c r455a sporlan sbqve b zp | EBSVE-11-ZP | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.37 |
| r404a r507 sporlan sbqse b zp | EBSSE-7-1/2-ZP | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.37 |
| liquid line od | 0.625 inches | p.46 | |
| suction line od | 1 5/8 inches | p.46 | |
| maximum line length 10 ft minimum room area ft2 | 100 | p.46 | |
| maximum line length 25 ft | 125 | p.46 | |
| maximum line length 50 ft | 166 | p.46 | |
| maximum line length 100 ft | 248 | p.46 | |
| motor hp | 0.3333333333333333 hp | p.12 | |
| motor fla | 4.8 amps | p.12 | |
| motor watts | 630 watts | p.12 | |
| mop | 15 amps | p.12 | |
| total watts | 9040 watts | p.12 | |
| total amps | 19.7 amps | p.12 | |
| defrost heaters 460 1 60 mop a | 25 | p.12 | |
| esp circuit mca | 24.6 amps | p.17 |
Sources: , . Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.
Orderable variants (1)
| Variant | Voltage | Availability |
|---|---|---|
| TMP349VE-S4E | 460/1/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 49 |
| capacity mbh | 49 |
| defrost | E |
| fan count | 3 |
| generation suffix | E |
| temp class | V |
| voltage | S4 |
Parts
8 factory parts for this unit: 8from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.
Expansion and refrigerant circuit
Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.
| Part | Part number | Description | Qty | List | Availability |
|---|---|---|---|---|---|
| Distributor nozzle | A10✓ | Distributor nozzle, Sporlan (Parker Hannifin) | - | - | Check availability |
| Electronic expansion valve | E3V45order as E3V45BWRC1✓ | Electronic expansion valve (EEV), Carel | - | - | Check availability |
| Safety check valve | CSOV13order as CSOV-13S✓ | Safety check valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Safety shutoff solenoid | SSOV10✓ | Safety shutoff solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Solenoid valve | B6order as B6S1✓ | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | - | - | Check availability |
| Solenoid valve | B9order as B9S2✓ | Solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| TXV | EBSSE-7-1/2-ZPorder as EBSSE-7-1/2-ZP40✓ | refrigerant: R404A/R507 | - | - | Check availability |
| TXV | EBSVE-11-ZPorder as EBSVE-11-ZP40✓ | refrigerant: R448A/R449A/R407A | - | - | Check availability |
Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KMP349VE-S4E | shared catalog stem ✓ |
| Bally | BMP349VE-S4E | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TMP349VE-S4E?
TMP349VE-S4E has a rated capacity of 51700 btu_h. See the specifications table for rating conditions.
What voltage does TMP349VE-S4E require?
TMP349VE-S4E runs on 460 V supply power.
Related models in TMP
Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.