TMP234VE-T3E
Trenton Refrigeration TMP evaporator.
Specifications
Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.
| Specification | Value | Conditions | Source |
|---|---|---|---|
| fan qty | 2 count | TMP + TMP-GEN-E p.5 ✓ | |
| capacity | 35500 btu_h | evap temp f: 0; refrigerant: R407A/R448A | p.5 |
| 34500 btu_h | evap temp f: 10; refrigerant: R407A/R448A | p.5 | |
| 33500 btu_h | evap temp f: 20; refrigerant: R407A/R448A | p.5 | |
| 30800 btu_h | evap temp f: 30; refrigerant: R407A/R448A | p.5 | |
| 28500 btu_h | evap temp f: 40; refrigerant: R407A/R448A | p.5 | |
| 28800 btu_h | evap temp f: 0; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 28000 btu_h | evap temp f: 10; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 27200 btu_h | evap temp f: 20; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 25000 btu_h | evap temp f: 30; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 23100 btu_h | evap temp f: 40; refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 35500 btu_h | evap temp f: 0; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 34500 btu_h | evap temp f: 10; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 33500 btu_h | evap temp f: 20; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 30800 btu_h | evap temp f: 30; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 28500 btu_h | evap temp f: 40; refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 35500 btu_h | evap temp f: 0; refrigerant: R407A/R448A/R449A | p.6 | |
| 34500 btu_h | evap temp f: 10; refrigerant: R407A/R448A/R449A | p.6 | |
| 33500 btu_h | evap temp f: 20; refrigerant: R407A/R448A/R449A | p.6 | |
| 30800 btu_h | evap temp f: 30; refrigerant: R407A/R448A/R449A | p.6 | |
| 28500 btu_h | evap temp f: 40; refrigerant: R407A/R448A/R449A | p.6 | |
| airflow | 6070 cfm | refrigerant: R407A/R448A | p.5 |
| 2860 l_s | refrigerant: R407A/R448A | p.5 | |
| 6070 cfm | refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 2860 l_s | refrigerant: R404A | TMP + TMP-GEN-E p.5 ✓ | |
| 6070 cfm | refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 2860 l_s | refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 6070 cfm | refrigerant: R407A/R448A/R449A | p.6 | |
| 2860 l_s | refrigerant: R407A/R448A/R449A | p.6 | |
| refrigerant charge | 5.4 lb | refrigerant: R407A | TMP + TMP-GEN-E p.5 ✓ |
| 2.5 kg | refrigerant: R407A | TMP + TMP-GEN-E p.5 ✓ | |
| 5 lbsources differ | refrigerant: R404A | TMP p.5 | |
| 9.2 lbsources differ | refrigerant: R404A | TMP-GEN-E p.7 | |
| 2.3 kgsources differ | refrigerant: R404A | TMP p.5 | |
| 4.2 kgsources differ | refrigerant: R404A | TMP-GEN-E p.7 | |
| 4.8 lbsources differ | refrigerant: R454A/R454C/R455A | TMP p.5 | |
| 4.9 lbsources differ | refrigerant: R454A/R454C/R455A | TMP-GEN-E p.4 | |
| 2.2 kg | refrigerant: R454A/R454C/R455A | TMP + TMP-GEN-E p.5 ✓ | |
| 5.2 lb | refrigerant: R448A | p.5 | |
| 2.4 kg | refrigerant: R448A | p.5 | |
| 5.2 lb | refrigerant: R448A/R449A | p.6 | |
| 2.4 kg | refrigerant: R448A/R449A | p.6 | |
| awef rating | 4.15 ratio | refrigerant: R404A/R507 | p.33 ✓ |
| 4.15 ratio | refrigerant: R407A | p.33 | |
| 4.15 ratio | refrigerant: R448A/R449A | p.33 | |
| 4.15 ratio | refrigerant: R454A | p.33 | |
| 4.15 ratio | refrigerant: R454C | p.33 | |
| 4.15 ratio | refrigerant: R455A | p.33 | |
| 4.15 ratio | fpi: 4 | p.31 | |
| suction od | 1 5/8 inches | TMP + TMP-GEN-E p.35 ✓ | |
| distributor inlet | 1 3/8 inchessources differ | TMP p.35 | |
| 0.875 inchessources differ | TMP p.35 | ||
| 1 1/8 inchessources differ | TMP p.35 | ||
| 1 3/8 inchessources differ | TMP-GEN-E p.34 | ||
| 1 1/8 inchessources differ | TMP-GEN-E p.33 | ||
| hot gas connection | 0.875 inches | p.35 | |
| shipping weight | 263 lb | TMP + TMP-GEN-E p.36 ✓ | |
| 119 kg | TMP + TMP-GEN-E p.36 ✓ | ||
| mca | 22.9 ampssources differ | TMP p.10 | |
| 16 ampssources differ | TMP-GEN-E p.11 | ||
| 23 ampssources differ | TMP-GEN-E p.11 | ||
| esp circuit 208 230 3 60 mop a | 25 | TMP + TMP-GEN-E p.10 ✓ | |
| voltage | 208 V | TMP + TMP-GEN-E p.? ✓ | |
| phase | 3 ph | TMP + TMP-GEN-E p.? ✓ | |
| frequency | 60 Hz | TMP + TMP-GEN-E p.? ✓ | |
| side port connection | 0.875 inches | p.34 | |
| drain pan loop conn od sweat | 0.875 | p.34 | |
| r454a sporlan sbqte b zp | EBSTE-8-ZP | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.37 |
| r448a r449a r407a r407c r454c r455a sporlan sbqve b zp | EBSVE-8-ZP | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.37 |
| r404a r507 sporlan sbqse b zp | EBSSE-6-ZP | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.37 |
| liquid line od | 0.625 inches | p.46 | |
| suction line od | 1 5/8 inches | p.46 | |
| maximum line length 10 ft minimum room area ft2 | 77 | p.46 | |
| maximum line length 25 ft | 101 | p.46 | |
| maximum line length 50 ft | 143 | p.46 | |
| maximum line length 100 ft | 225 | p.46 | |
| motor hp | 0.25 hp | p.11 | |
| motor fla | 4.4 amps | p.11 | |
| motor watts | 420 watts | p.11 | |
| mop | 20 amps | p.11 | |
| total watts | 6190 watts | p.11 | |
| total amps | 18.3 amps | p.11 | |
| defrost heaters 208 230 3 60 mop a | 25 | p.11 | |
| esp circuit mca | 22.9 amps | p.16 |
Sources: , . Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.
Orderable variants (1)
| Variant | Voltage | Availability |
|---|---|---|
| TMP234VE-T3E | 208-230/3/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 34 |
| capacity mbh | 34 |
| defrost | E |
| fan count | 2 |
| generation suffix | E |
| temp class | V |
| voltage | T3 |
Parts
7 factory parts for this unit: 7from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.
Expansion and refrigerant circuit
Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.
| Part | Part number | Description | Qty | List | Availability |
|---|---|---|---|---|---|
| Distributor nozzle | E6order as E6S140✓ | Distributor nozzle, Sporlan (Parker Hannifin) | - | - | Check availability |
| Electronic expansion valve | E2V35order as E2V35FSMC0✓ | Electronic expansion valve (EEV), Carel | - | - | Check availability |
| Safety check valve | CSOV13order as CSOV-13S✓ | Safety check valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Safety shutoff solenoid | SSOV10✓ | Safety shutoff solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Solenoid valve | B6order as B6S1✓ | Solenoid valve; Solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| TXV | EBSSE-6-ZP✓ | refrigerant: R404A/R507 | - | - | Check availability |
| TXV | EBSVE-8-ZPorder as EBSVE-8-ZP40✓ | refrigerant: R448A/R449A/R407A | - | - | Check availability |
Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KMP234VE-T3E | shared catalog stem ✓ |
| Bally | BMP234VE-T3E | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TMP234VE-T3E?
TMP234VE-T3E has a rated capacity of 35500 btu_h. See the specifications table for rating conditions.
What voltage does TMP234VE-T3E require?
TMP234VE-T3E runs on 208 V supply power.