| Specification | Value | Conditions | Source |
|---|---|---|---|
| fpi | 7 | p.4 | |
| fan qty | 1 count | p.4 | |
| 1 count | p.15 | ||
| 1 count | p.16 | ||
| 1 count | refrigerant: R407A/R407C/R448A/R449A | p.3 | |
| 1 count | refrigerant: R404A/R507 | p.3 | |
| motor hp | 0.1 hp | p.4 | |
| motor fla | 1 amps | p.4 | |
| total watts | 95 watts | p.4 | |
| mca | 1.3 amps | p.4 | |
| max fuse | 15 amps | p.4 | |
| awef rating | 9 ratio | refrigerant: R404A/R507 | p.15 |
| 9 ratio | refrigerant: R407A/R407C | p.15 | |
| 9 ratio | refrigerant: R448A/R449A | p.15 | |
| suction od | 0.875 inches | p.15 | |
| 22 mm | p.15 | ||
| distributor inlet | 0.5 inches | p.15 | |
| 13 mm | p.15 | ||
| hot gas connection | 0.5 inches | p.15 | |
| 13 mm | p.15 | ||
| shipping weight | 105 lb | p.15 | |
| 48 kg | p.15 | ||
| dimension A | 66 7/8 inches | p.16 | |
| 1699 mm | p.16 | ||
| dimension B | 9 9/16 inches | p.16 | |
| 243 mm | p.16 | ||
| dimension C | 27 1/2 inches | p.16 | |
| 699 mm | p.16 | ||
| dimension D | 27 1/2 inches | p.16 | |
| 699 mm | p.16 | ||
| dimension E | - inches | p.16 | |
| - mm | p.16 | ||
| dimension F | - inches | p.16 | |
| - mm | p.16 | ||
| dimension G | - inches | p.16 | |
| - mm | p.16 | ||
| txv capacity rating | 8670 btu_h | refrigerant: R407A/R407C/R448A/R449A | p.18 |
| 13000 btu_h | refrigerant: R407A/R407C/R448A/R449A | p.18 | |
| 7040 btu_h | refrigerant: R404A/R507 | p.18 | |
| 10600 btu_h | refrigerant: R404A/R507 | p.18 | |
| txv model | SBQVE-A-C part_number | refrigerant: R407A/R407C/R448A/R449A | p.18 |
| SBQVE-A-C part_number | refrigerant: R407A/R407C/R448A/R449A | p.18 | |
| SBQSE-A-C part_number | refrigerant: R404A/R507 | p.18 | |
| SBQSE-B-C part_number | refrigerant: R404A/R507 | p.18 | |
| E2V11 part_number | refrigerant: R407A/R407C/R448A/R449A | p.19 | |
| E2V11 part_number | refrigerant: R404A/R507 | p.19 | |
| distributor nozzle | J-1 part_id | p.18 | |
| 1 part_id | refrigerant: R407A/R407C/R448A/R449A | p.19 | |
| 1 part_id | refrigerant: R404A/R507 | p.19 | |
| solenoid valve | 3 part_number | refrigerant: R407A/R407C/R448A/R449A | p.19 |
| 3 part_number | refrigerant: R404A/R507 | p.19 | |
| capacity | 8670 btu_h | evap temp f: 25 · refrigerant: R407A/R407C/R448A/R449A | p.3 |
| 8583 btu_h | evap temp f: 15 · refrigerant: R407A/R407C/R448A/R449A | p.3 | |
| 8500 btu_h | evap temp f: 10 · refrigerant: R407A/R407C/R448A/R449A | p.3 | |
| 7040 btu_h | evap temp f: 25 · refrigerant: R404A/R507 | p.3 | |
| 6970 btu_h | evap temp f: 15 · refrigerant: R404A/R507 | p.3 | |
| 6900 btu_h | evap temp f: 10 · refrigerant: R404A/R507 | p.3 | |
| airflow | 1120 cfm | refrigerant: R407A/R407C/R448A/R449A | p.3 |
| 529 l_s | refrigerant: R407A/R407C/R448A/R449A | p.3 | |
| 1120 cfm | refrigerant: R404A/R507 | p.3 | |
| 529 l_s | refrigerant: R404A/R507 | p.3 | |
| refrigerant charge | 4.4 lb | refrigerant: R407A/R407C/R448A/R449A | p.3 |
| 2 kg | refrigerant: R407A/R407C/R448A/R449A | p.3 | |
| 4 lb | refrigerant: R404A/R507 | p.3 | |
| 1.8 kg | refrigerant: R404A/R507 | p.3 | |
| voltage | 208 V | p.? | |
| phase | 1 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: TLV_1109292 · extraction with per-cell provenance · verify before purchase. · variants from distributor API snapshot
Orderable variants (2)
| Variant | Voltage | Availability |
|---|---|---|
| TLV109MA-S2D | 208-230/1/60 | Check availability |
| TLV109MA-S2D-C | 208-230/1/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 09 |
| defrost | MA |
| fan count | 1 |
| generation suffix | D |
| voltage | S2 |
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KLV109MA-S2D | shared catalog stem ✓ |
| Bally | BLV109MA-S2D | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TLV109MA-S2D?
TLV109MA-S2D has a rated capacity of 8670 btu_h. See the specifications table for rating conditions.
What voltage does TLV109MA-S2D require?
TLV109MA-S2D runs on 208 V supply power.