TLP644ME-T3E
Trenton Refrigeration TLP evaporator.
Specifications
Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.
| Specification | Value | Conditions | Source |
|---|---|---|---|
| fan qty | 6 count | refrigerant: R454A/R454C/R455A | p.3 |
| 6 count | TLP + TLP-GEN-E p.6 ✓ | ||
| capacity | 44000 btu_h | evap temp f: 25; refrigerant: R454A/R454C/R455A | TLP + TLP-GEN-E p.3 ✓ |
| 43600 btu_h | evap temp f: 15; refrigerant: R454A/R454C/R455A | TLP + TLP-GEN-E p.3 ✓ | |
| 43120 btu_h | evap temp f: 10; refrigerant: R454A/R454C/R455A | TLP + TLP-GEN-E p.3 ✓ | |
| 44000 btu_h | evap temp f: 25; refrigerant: R407A/R407C/R448A/R449A | p.5 | |
| 43600 btu_h | evap temp f: 15; refrigerant: R407A/R407C/R448A/R449A | p.5 | |
| 43120 btu_h | evap temp f: 10; refrigerant: R407A/R407C/R448A/R449A | p.5 | |
| 39400 btu_h | evap temp f: 0; refrigerant: R404A/R507 | p.6 | |
| 39000 btu_h | evap temp f: 10; refrigerant: R404A/R507 | p.6 | |
| 38610 btu_h | evap temp f: 20; refrigerant: R404A/R507 | p.6 | |
| airflow | 4080 cfm | refrigerant: R454A/R454C/R455A | p.3 |
| 1930 l_s | refrigerant: R454A/R454C/R455A | p.3 | |
| 4080 cfm | p.5 | ||
| 1930 l_s | p.3 | ||
| refrigerant charge | 4.3 lb | refrigerant: R454A/R454C/R455A | TLP + TLP-GEN-E p.3 ✓ |
| (1.9) kg | refrigerant: R454A/R454C/R455A | TLP + TLP-GEN-E p.3 ✓ | |
| 4.3 lb | refrigerant: R407A/R407C/R448A/R449A | p.5 | |
| (1.9) kg | refrigerant: R407A/R407C/R448A/R449A | p.5 | |
| 4.4 lb | refrigerant: R404A/R507 | p.6 | |
| (2.0) kg | refrigerant: R404A/R507 | p.6 | |
| awef rating | 9 ratio | refrigerant: R454A | p.16 ✓ |
| 9 ratio | refrigerant: R454C | p.16 | |
| 9 ratio | refrigerant: R455A | p.16 | |
| 9 ratio | fpi: 6 | p.24 | |
| liquid line od | 0.5 inches | TLP + TLP-GEN-E p.25 ✓ | |
| 13 mm | TLP + TLP-GEN-E p.26 ✓ | ||
| suction od | 1 3/8 inches | TLP + TLP-GEN-E p.25 ✓ | |
| 35 mm | p.26 | ||
| maximum line length 10 ft minimum room area ft2 | 63 | p.25 | |
| maximum line length 25 ft | 80 | TLP + TLP-GEN-E p.25 ✓ | |
| maximum line length 50 ft | 107 | TLP + TLP-GEN-E p.25 ✓ | |
| maximum line length 100 ft | 163 | TLP + TLP-GEN-E p.25 ✓ | |
| maximum line length 3m minimum room area m2 | 6 | p.26 | |
| maximum line length 7 6m | 7 | TLP + TLP-GEN-E p.26 ✓ | |
| maximum line length 15 2m | 10 | TLP + TLP-GEN-E p.26 ✓ | |
| maximum line length 30 5m | 15 | TLP + TLP-GEN-E p.26 ✓ | |
| model tlp | 631LEsources differ | TLP p.18 | |
| 627VEsources differ | TLP p.18 | ||
| TLPsources differ | TLP-GEN-E p.26 | ||
| TLP | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.29 | |
| shipping weight | 207 lb | TLP + TLP-GEN-E p.18 ✓ | |
| 94 kgsources differ | TLP p.18 | ||
| (94) kgsources differ | TLP-GEN-E p.27 | ||
| motor hp | 0.06666666666666667 hp | TLP + TLP-GEN-E p.6 ✓ | |
| motor fla | 3.6 amps | TLP + TLP-GEN-E p.6 ✓ | |
| total watts | 360 wattssources differ | TLP p.6 | |
| 5230 wattssources differ | TLP p.6 | ||
| 5230 wattssources differ | TLP-GEN-E p.10 | ||
| mca | 3.8 ampssources differ | TLP p.6 | |
| 28.4 ampssources differ | TLP p.6 | ||
| 18 ampssources differ | TLP p.6 | ||
| 18.3 ampssources differ | TLP p.9 | ||
| 3.8 ampssources differ | TLP-GEN-E p.10 | ||
| 28.4 ampssources differ | TLP-GEN-E p.10 | ||
| 18 ampssources differ | TLP-GEN-E p.10 | ||
| mop | 15 amps | TLP + TLP-GEN-E p.6 ✓ | |
| total amps | 22.7 ampssources differ | TLP p.6 | |
| 15 ampssources differ | TLP p.6 | ||
| 22.7 ampssources differ | TLP-GEN-E p.10 | ||
| 15 ampssources differ | TLP-GEN-E p.10 | ||
| defrost heaters 208 230 1 60 mop a | 30 | TLP + TLP-GEN-E p.6 ✓ | |
| defrost heaters 208 230 3 60 mop a | 20 | TLP + TLP-GEN-E p.6 ✓ | |
| esp circuit 208 230 3 60 mop a | 20 | p.9 | |
| voltage | 208 V | TLP + TLP-GEN-E p.? ✓ | |
| phase | 3 ph | TLP + TLP-GEN-E p.? ✓ | |
| frequency | 60 Hz | TLP + TLP-GEN-E p.? ✓ | |
| air flow 30 f 34 c | 4080 | evap temp f: 30; refrigerant: R404A/R507 | p.6 |
| air flow 40 f 40 c | 1930 | evap temp f: 40; refrigerant: R404A/R507 | p.6 |
| dimension unparsed | 110 1/4sources differ | TLP-GEN-E p.26 | |
| 2800sources differ | TLP-GEN-E p.26 | ||
| 48 5/8sources differ | TLP-GEN-E p.26 | ||
| 1235sources differ | TLP-GEN-E p.26 | ||
| 1 1/8sources differ | TLP-GEN-E p.26 | ||
| distributor inlet | 0.875 inches | p.26 | |
| hot gas connection | 0.625 inches | p.26 | |
| r454a sporlan ebqte aaa c | EBQTE-C-C | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.29 |
| r448a r449a r407a r407c r454c r455a sporlan ebqve aaa c | EBQVE-C-C | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.29 |
| r404a r507 sporlan ebqse aa c | EBSSE-6-C | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | p.29 |
| unclassified part | TLP part_number | p.31 | |
| suction line od | 1 3/8 inches | p.39 | |
| 35 mm | p.40 | ||
| maximum line length 10 ft minimum room area ft | 63 | p.39 | |
| maximum line length 3m minimum room area ft | 6 | p.40 | |
| model 104le | 631LE | p.27 | |
| model 103ve | 627VE | p.27 | |
| motor watts | 360 watts | p.10 | |
| voltage 208 230 1 60 | 208-230/3/60 | p.46 |
Sources: , . Extraction with per-cell provenance. Verify before purchase.
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 44 |
| capacity mbh | 44 |
| defrost | E |
| fan count | 6 |
| generation suffix | E |
| temp class | M |
| voltage | T3 |
Parts
7 factory parts for this unit: 7from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.
Expansion and refrigerant circuit
Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.
| Part | Part number | Description | Qty | List | Availability |
|---|---|---|---|---|---|
| Distributor nozzle | G3✓ | Distributor nozzle, Sporlan (Parker Hannifin) | - | - | Check availability |
| Electronic expansion valve | E2V35order as E2V35FSMC0✓ | Electronic expansion valve (EEV), Carel | - | - | Check availability |
| Electronic expansion valve | RSV 400✓ | Electronic expansion valve (EEV), KE2 Therm Solutions | - | - | Check availability |
| Safety check valve | CSOV11order as CSOV-11S✓ | Safety check valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Safety shutoff solenoid | SSOV6✓ | Safety shutoff solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Solenoid valve | B6order as B6S1✓ | refrigerant: R404A/R407A/R407C/R448A/R449A/R454A/R454C/R455A/R507 | - | - | Check availability |
| Solenoid valve | E6order as E6S140✓ | Solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.
Cross references
No sister-brand equivalents cataloged for this model.
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TLP644ME-T3E?
TLP644ME-T3E has a rated capacity of 44000 btu_h. See the specifications table for rating conditions.
What voltage does TLP644ME-T3E require?
TLP644ME-T3E runs on 208 V supply power.
Related models in TLP