TLP537ME-T3E

Trenton Refrigeration TLP evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
fan qty5 countp.3
5 countTLP + TLP-GEN-E p.6
capacity36700 btu_hTLP + TLP-GEN-E p.3
36300 btu_hTLP + TLP-GEN-E p.3
35970 btu_hTLP + TLP-GEN-E p.3
36700 btu_hp.5
36300 btu_hp.5
35970 btu_hp.5
32900 btu_hp.6
32600 btu_hp.6
32240 btu_hp.6
airflow3400 cfmp.3
1600 l_sp.3
3400 cfmp.3
1600 l_sp.3
refrigerant charge3.7 lbTLP + TLP-GEN-E p.3
(1.7) kgTLP + TLP-GEN-E p.3
3.7 lbp.5
(1.7) kgp.5
3.8 lbp.6
(1.7) kgp.6
awef rating9 ratiop.16
9 ratiop.16
9 ratiop.16
9 ratiop.24
liquid line od0.5 inchesTLP + TLP-GEN-E p.25
13 mmTLP + TLP-GEN-E p.26
suction od1 3/8 inchesTLP + TLP-GEN-E p.25
35 mmp.26
maximum line length 10 ft minimum room area ft256p.25
maximum line length 25 ft73TLP + TLP-GEN-E p.25
maximum line length 50 ft100TLP + TLP-GEN-E p.25
maximum line length 100 ft156TLP + TLP-GEN-E p.25
maximum line length 3m minimum room area m25p.26
maximum line length 7 6m7TLP + TLP-GEN-E p.26
maximum line length 15 2m9TLP + TLP-GEN-E p.26
maximum line length 30 5m14TLP + TLP-GEN-E p.26
model tlp526LEsources differTLP p.18
524VEsources differTLP p.18
TLPsources differTLP-GEN-E p.26
TLPp.29
shipping weight176 lbTLP + TLP-GEN-E p.18
80 kgsources differTLP p.18
(80) kgsources differTLP-GEN-E p.27
motor hp0.06666666666666667 hpTLP + TLP-GEN-E p.6
motor fla3 ampsTLP + TLP-GEN-E p.6
total watts300 wattssources differTLP p.6
4400 wattssources differTLP p.6
4400 wattssources differTLP-GEN-E p.10
mca3.2 ampssources differTLP p.6
23.9 ampssources differTLP p.6
15 ampssources differTLP p.6
15.4 ampssources differTLP p.9
3.2 ampssources differTLP-GEN-E p.10
23.9 ampssources differTLP-GEN-E p.10
15 ampssources differTLP-GEN-E p.10
mop15 ampsTLP + TLP-GEN-E p.6
total amps19.1 ampssources differTLP p.6
12 ampssources differTLP p.6
19.1 ampssources differTLP-GEN-E p.10
12 ampssources differTLP-GEN-E p.10
defrost heaters 208 230 1 60 mop a25TLP + TLP-GEN-E p.6
defrost heaters 208 230 3 60 mop a20TLP + TLP-GEN-E p.6
esp circuit 208 230 3 60 mop a20p.9
voltage208 VTLP + TLP-GEN-E p.?
phase3 phTLP + TLP-GEN-E p.?
frequency60 HzTLP + TLP-GEN-E p.?
air flow 30 f 34 c3400p.6
air flow 40 f 40 c1600p.6
dimension unparsed94 1/4sources differTLP-GEN-E p.26
2394sources differTLP-GEN-E p.26
32 5/8sources differTLP-GEN-E p.26
829sources differTLP-GEN-E p.26
48 5/8sources differTLP-GEN-E p.26
1235sources differTLP-GEN-E p.26
1 1/8sources differTLP-GEN-E p.26
distributor inlet0.5 inchesp.26
hot gas connection0.5 inchesp.26
r454a sporlan ebqte aaa cEBQTE-C-Cp.29
r448a r449a r407a r407c r454c r455a sporlan ebqve aaa cEBQVE-C-Cp.29
r404a r507 sporlan ebqse aa cEBSSE-6-Cp.29
unclassified partTLP part_numberp.31
suction line od1 3/8 inchesp.39
35 mmp.40
maximum line length 10 ft minimum room area ft56p.39
maximum line length 3m minimum room area ft5p.40
model 104le526LEp.27
model 103ve524VEp.27
motor watts300 wattsp.10
voltage 208 230 1 60208-230/3/60p.46

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

,

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP-GEN-E_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase.

Nomenclature

Position / meaningValue
capacity code37
capacity mbh37
defrostE
fan count5
generation suffixE
temp classM
voltageT3

Parts

7 factory parts for this unit: 7from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.

PartPart numberQtyListAvailability
Distributor nozzleL2-1/2--Check availability
Electronic expansion valveE2V35order as E2V35FSMC0--Check availability
Electronic expansion valveRSV 320--Check availability
Safety check valveCSOV11order as CSOV-11S--Check availability
Safety shutoff solenoidSSOV6--Check availability
Solenoid valveB6order as B6S1--Check availability
Solenoid valveE6order as E6S140--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

No sister-brand equivalents cataloged for this model.

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of TLP537ME-T3E?

TLP537ME-T3E has a rated capacity of 36700 btu_h. See the specifications table for rating conditions.

What voltage does TLP537ME-T3E require?

TLP537ME-T3E runs on 208 V supply power.

Related models in TLP

Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.