TLP421LE-S2D

Trenton Refrigeration TLP evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
capacity22470 btu_hp.3
21800 btu_hp.3
21200 btu_hp.3
19500 btu_hp.3
18000 btu_hp.3
22470 btu_hp.5
21800 btu_hp.5
21200 btu_hp.5
19500 btu_hp.5
18000 btu_hp.5
21840 btu_hp.7
21200 btu_hp.7
20600 btu_hp.7
19000 btu_hp.7
17510 btu_hp.7
airflow2720 cfmp.3
1280 l_sp.3
2720 cfmp.5
1280 l_sp.5
refrigerant charge3 lbp.3
(1.3) kgp.3
3 lbp.5
(1.3) kgp.5
3 lbp.7
(1.4) kgp.7
awef rating4.15 ratiop.16
4.15 ratiop.16
4.15 ratiop.16
4.15 ratiop.24
liquid line od0.5 inchesTLP + TLP-GEN-E p.25
13 mmTLP + TLP-GEN-E p.26
suction od1 1/8 inchesTLP + TLP-GEN-E p.25
29 mmp.26
maximum line length 10 ft minimum room area ft246p.25
maximum line length 25 ft61TLP + TLP-GEN-E p.25
maximum line length 50 ft87TLP + TLP-GEN-E p.25
maximum line length 100 ft137TLP + TLP-GEN-E p.25
maximum line length 3m minimum room area m24p.26
maximum line length 7 6m6TLP + TLP-GEN-E p.26
maximum line length 15 2m8TLP + TLP-GEN-E p.26
maximum line length 30 5m13TLP + TLP-GEN-E p.26
fan qty4 countTLP + TLP-GEN-E p.6
motor hp0.06666666666666667 hpTLP + TLP-GEN-E p.6
motor fla2.4 ampsTLP + TLP-GEN-E p.6
total watts240 wattssources differTLP p.6
3560 wattssources differTLP p.6
3560 wattssources differTLP-GEN-E p.10
mca2.6 ampssources differTLP p.6
19.3 ampssources differTLP p.6
12 ampssources differTLP p.6
2.6 ampssources differTLP-GEN-E p.10
19.3 ampssources differTLP-GEN-E p.10
12 ampssources differTLP-GEN-E p.10
mop15 ampsTLP + TLP-GEN-E p.6
total amps15.5 ampssources differTLP p.6
10 ampssources differTLP p.6
15.5 ampssources differTLP-GEN-E p.10
10 ampssources differTLP-GEN-E p.10
defrost heaters 208 230 1 60 mop a20TLP + TLP-GEN-E p.6
defrost heaters 208 230 3 60 mop a15TLP + TLP-GEN-E p.6
voltage 208 230 1 60208-230/1/60p.32
1 x evaporator defrost kit dfk 02DFK-02p.32
1 x evaporator fuse package fp 004FP-006p.32
2 x evaporator defrost kit dfk 06 dfk 07DFK-06 DFK-07p.32
2 x evaporator fuse package fp 008FP-015p.32
voltage208 VTLP + TLP-GEN-E p.?
phase1 phTLP + TLP-GEN-E p.?
frequency60 HzTLP + TLP-GEN-E p.?
model tlpTLPp.26
TLPp.29
dimension unparsed78 1/4sources differTLP-GEN-E p.26
1988sources differTLP-GEN-E p.26
32 5/8sources differTLP-GEN-E p.26
829sources differTLP-GEN-E p.26
0.875sources differTLP-GEN-E p.26
distributor inlet0.875 inchesp.26
hot gas connection0.625 inchesp.26
suction line od1 1/8 inchesp.39
29 mmp.40
maximum line length 10 ft minimum room area ft46p.39
maximum line length 3m minimum room area ft4p.40
unclassified partTLP part_numberp.31
motor watts240 wattsp.10
r454a sporlan ebqte aa zpEBQTE-C-ZPp.29
r448a r449a r407a r407c r454c r455a sporlan ebqve aa zpEBQVE-C-ZPp.29
r404a r507 sporlan ebqse aa zpEBQSE-C-ZPp.29

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

,

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP-GEN-E_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.

Orderable variants (1)

VariantVoltageAvailability
TLP421LE-S2D208-230/1/60Check availability

Nomenclature

Position / meaningValue
capacity code21
capacity mbh21
defrostE
fan count4
generation suffixD
temp classL
voltageS2

Parts

6 factory parts for this unit: 6from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.

PartPart numberQtyListAvailability
Distributor nozzleG4--Check availability
Electronic expansion valveE2V35order as E2V35FSMC0--Check availability
Electronic expansion valveRSV220--Check availability
Safety check valveCSOV9order as CSOV-9S--Check availability
Safety shutoff solenoidSSOV6--Check availability
Solenoid valveE5order as E5S130--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

BrandEquivalent modelBasis
KeepRiteKLP421LE-S2Dshared catalog stem
BallyBLP421LE-S2Dshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of TLP421LE-S2D?

TLP421LE-S2D has a rated capacity of 22470 btu_h. See the specifications table for rating conditions.

What voltage does TLP421LE-S2D require?

TLP421LE-S2D runs on 208 V supply power.

Related models in TLP

Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.