TLP314LE-S2D

Trenton Refrigeration TLP evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
fan qty3 countp.3
3 countTLP + TLP-GEN-E p.6
capacity14730 btu_hp.3
14300 btu_hp.3
13900 btu_hp.3
12800 btu_hp.3
11800 btu_hp.3
14730 btu_hp.5
14300 btu_hp.5
13900 btu_hp.5
12800 btu_hp.5
11800 btu_hp.5
14420 btu_hp.7
14000 btu_hp.7
13600 btu_hp.7
12500 btu_hp.7
11560 btu_hp.7
airflow2115 cfmp.3
1000 l_sp.3
2115 cfmp.5
1000 l_sp.5
refrigerant charge1.9 lbp.3
(0.9) kgp.3
1.9 lbp.5
(0.9) kgp.5
2 lbp.7
(0.9) kgp.7
awef rating4.07 ratiop.16
4.07 ratiop.16
4.07 ratiop.16
4.07 ratiop.24
liquid line od0.375 inchesTLP + TLP-GEN-E p.25
10 mmTLP + TLP-GEN-E p.26
suction od0.875 inchesTLP + TLP-GEN-E p.25
22 mmp.26
maximum line length 10 ft minimum room area ft229p.25
maximum line length 25 ft37TLP + TLP-GEN-E p.25
maximum line length 50 ft50TLP + TLP-GEN-E p.25
maximum line length 100 ft76TLP + TLP-GEN-E p.25
maximum line length 3m minimum room area m23p.26
maximum line length 7 6m3TLP + TLP-GEN-E p.26
maximum line length 15 2m5TLP + TLP-GEN-E p.26
maximum line length 30 5m7TLP + TLP-GEN-E p.26
motor hp0.06666666666666667 hpTLP + TLP-GEN-E p.6
motor fla1.8 ampsTLP + TLP-GEN-E p.6
total watts180 wattssources differTLP p.6
2730 wattssources differTLP p.6
2730 wattssources differTLP-GEN-E p.10
mca2 ampssources differTLP p.6
14.8 ampssources differTLP p.6
10 ampssources differTLP p.6
2 ampssources differTLP-GEN-E p.10
14.8 ampssources differTLP-GEN-E p.10
10 ampssources differTLP-GEN-E p.10
mop15 ampsTLP + TLP-GEN-E p.6
total amps11.9 ampssources differTLP p.6
7.7 ampssources differTLP p.6
11.9 ampssources differTLP-GEN-E p.10
7.7 ampssources differTLP-GEN-E p.10
defrost heaters 208 230 1 60 mop a15TLP + TLP-GEN-E p.6
defrost heaters 208 230 3 60 mop a15TLP + TLP-GEN-E p.6
snaf fo 13p.32
voltage 208 230 1 60208-230/1/60p.32
1 x evaporator defrost kit dfk 02DFK-02p.32
1 x evaporator fuse package fp 004FP-004p.32
2 x evaporator defrost kit dfk 06 dfk 07DFK-06 DFK-07p.32
2 x evaporator fuse package fp 008FP-008p.32
voltage208 VTLP + TLP-GEN-E p.?
phase1 phTLP + TLP-GEN-E p.?
frequency60 HzTLP + TLP-GEN-E p.?
model tlpTLPp.26
TLPp.29
dimension unparsed62 1/4sources differTLP-GEN-E p.26
1581sources differTLP-GEN-E p.26
49 1/4sources differTLP-GEN-E p.26
1251sources differTLP-GEN-E p.26
N/Asources differTLP-GEN-E p.26
0.875sources differTLP-GEN-E p.26
distributor inlet0.5 inchesp.26
hot gas connection0.5 inchesp.26
suction line od0.875 inchesp.39
22 mmp.40
maximum line length 10 ft minimum room area ft29p.39
maximum line length 3m minimum room area ft3p.40
unclassified partTLP part_numberp.31
motor watts180 wattsp.10
r454a sporlan ebqte aa zpEBQTE-B-ZPp.29
r448a r449a r407a r407c r454c r455a sporlan ebqve aa zpEBQVE-B-ZPp.29
r404a r507 sporlan ebqse aa zpEBQSE-B-ZPp.29

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

,

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP-GEN-E_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.

Orderable variants (1)

VariantVoltageAvailability
TLP314LE-S2D208-230/1/60Check availability

Nomenclature

Position / meaningValue
capacity code14
capacity mbh14
defrostE
fan count3
generation suffixD
temp classL
voltageS2

Parts

6 factory parts for this unit: 6from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.

PartPart numberQtyListAvailability
Distributor nozzleL2--Check availability
Electronic expansion valveE2V24order as E2V24FWBC1--Check availability
Electronic expansion valveRSV220--Check availability
Safety check valveCSOV7order as CSOV-7S--Check availability
Safety shutoff solenoidSSOV6--Check availability
Solenoid valveE5order as E5S130--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

BrandEquivalent modelBasis
KeepRiteKLP314LE-S2Dshared catalog stem
BallyBLP314LE-S2Dshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of TLP314LE-S2D?

TLP314LE-S2D has a rated capacity of 14730 btu_h. See the specifications table for rating conditions.

What voltage does TLP314LE-S2D require?

TLP314LE-S2D runs on 208 V supply power.