TLP242ME-T3E
Trenton Refrigeration TLP low profile evaporatorsavailable options evaporator.
Specifications
Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.
| Specification | Value | Conditions | Source |
|---|---|---|---|
| fan qty | 4 count | refrigerant: R454A/R454C/R455A | p.3 |
| 4 count | p.6 | ||
| capacity | 24400 btu_h | evap temp f: 25; refrigerant: R454A/R454C/R455A | p.3 |
| 24200 btu_h | evap temp f: 15; refrigerant: R454A/R454C/R455A | p.3 | |
| 23910 btu_h | evap temp f: 10; refrigerant: R454A/R454C/R455A | p.3 | |
| airflow | 2820 cfm | refrigerant: R454A/R454C/R455A | p.3 |
| 1330 l_s | refrigerant: R454A/R454C/R455A | p.3 | |
| refrigerant charge | 2.5 lb | refrigerant: R454A/R454C/R455A | p.3 |
| (1.1) kg | refrigerant: R454A/R454C/R455A | p.3 | |
| awef rating | 9 ratio | refrigerant: R454A | p.16 |
| 9 ratio | refrigerant: R454C | p.16 | |
| 9 ratio | refrigerant: R455A | p.16 | |
| model tlp | 418LEsources differ | TLP p.18 | |
| 418VEsources differ | TLP p.18 | ||
| shipping weight | 127 lb | p.18 | |
| 58 kg | p.18 | ||
| motor hp | 0.06666666666666667 hp | p.6 | |
| motor fla | 2.4 amps | p.6 | |
| total watts | 240 wattssources differ | TLP p.6 | |
| 3560 wattssources differ | TLP p.6 | ||
| mca | 2.6 ampssources differ | TLP p.6 | |
| 19.3 ampssources differ | TLP p.6 | ||
| 12 ampssources differ | TLP p.6 | ||
| 12.5 ampssources differ | TLP p.9 | ||
| mop | 15 amps | p.6 | |
| total amps | 15.5 ampssources differ | TLP p.6 | |
| 10 ampssources differ | TLP p.6 | ||
| defrost heaters 208 230 1 60 mop a | 20 | p.6 | |
| defrost heaters 208 230 3 60 mop a | 15 | p.6 | |
| esp circuit 208 230 3 60 mop a | 15 | p.9 | |
| voltage | 208 V | p.? | |
| phase | 3 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: . Extraction with per-cell provenance. Verify before purchase.
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 42 |
| capacity mbh | 42 |
| defrost | E |
| fan count | 2 |
| generation suffix | E |
| temp class | M |
| voltage | T3 |
Parts
6 factory parts for this unit: 6from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.
Expansion and refrigerant circuit
Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.
| Part | Part number | Description | Qty | List | Availability |
|---|---|---|---|---|---|
| Distributor nozzle | L2✓ | Distributor nozzle, Sporlan (Parker Hannifin) | - | - | Check availability |
| Electronic expansion valve | E2V24order as E2V24FWBC1✓ | Electronic expansion valve (EEV), Carel | - | - | Check availability |
| Electronic expansion valve | RSV 320✓ | Electronic expansion valve (EEV), KE2 Therm Solutions | - | - | Check availability |
| Safety check valve | CSOV9order as CSOV-9S✓ | Safety check valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Safety shutoff solenoid | SSOV6✓ | Safety shutoff solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Solenoid valve | E5order as E5S130✓ | Solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.
Cross references
No sister-brand equivalents cataloged for this model.
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TLP242ME-T3E?
TLP242ME-T3E has a rated capacity of 24400 btu_h. See the specifications table for rating conditions.
What voltage does TLP242ME-T3E require?
TLP242ME-T3E runs on 208 V supply power.
Related models in TLP
Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.