Trenton Refrigeration · TLP · Low Profile Evaporatorsavailable Options
TLP215ME-T3E
Trenton Refrigeration TLP low profile savailable option evaporator.
50 extracted specifications, each traceable to its source document and page.
Specifications
| Specification | Value | Conditions | Source |
|---|---|---|---|
| capacity | 14900 btu_h | evap temp f: 25 | p.3 |
| 14800 btu_h | evap temp f: 15 | p.3 | |
| 14600 btu_h | evap temp f: 10 | p.3 | |
| airflow | 1360 cfm | p.3 | |
| 640 l_s | p.3 | ||
| refrigerant charge | 1.9 lb | p.3 | |
| (0.8) kg | p.3 | ||
| awef rating | 9 ratio | refrigerant: R454A | p.16 |
| 9 ratio | refrigerant: R454C | p.16 | |
| 9 ratio | refrigerant: R455A | p.16 | |
| distributor nozzle | L1 part_id | p.19 | |
| electronic expansion valve | RSV 220 part_number | p.19 | |
| E2V24 part_number | p.19 | ||
| solenoid valve | E3 part_number | p.19 | |
| safety solenoid valve | SSOV3 part_number | p.19 | |
| safety check valve | CSOV7 part_number | p.19 | |
| liquid line od in | 0.375 | p.25 | |
| suction od | 0.875 inches | p.25 | |
| 22 inches | p.26 | ||
| maximum line length 10 ft minimum room area ft2 | 28 | p.25 | |
| maximum line length 25 ft | 37 | p.25 | |
| maximum line length 50 ft | 50 | p.25 | |
| maximum line length 100 ft | 78 | p.25 | |
| liquid line od mm | 10 | p.26 | |
| maximum line length 3m minimum room area m2 | 3 | p.26 | |
| maximum line length 7 6m | 3 | p.26 | |
| maximum line length 15 2m | 5 | p.26 | |
| maximum line length 30 5m | 7 | p.26 | |
| model tlp | 211LE | p.18 | |
| 211VE | p.18 | ||
| shipping weight | 84 lb | p.18 | |
| 38 kg | p.18 | ||
| fan qty | 2 count | p.6 | |
| motor hp | 0.06666666666666667 hp | p.6 | |
| motor fla | 1.2 amps | p.6 | |
| total watts | 120 watts | p.6 | |
| 1890 watts | p.6 | ||
| mca | 1.4 amps | p.6 | |
| 10.3 amps | p.6 | ||
| 6.7 amps | p.6 | ||
| 6.7 amps | p.9 | ||
| fan motors standard ec motors mop a | 15 | p.6 | |
| total amps | 8.2 amps | p.6 | |
| 5.3 amps | p.6 | ||
| defrost heaters 208 230 1 60 mop a | 15 | p.6 | |
| defrost heaters 208 230 3 60 mop a | 15 | p.6 | |
| esp circuit 208 230 3 60 mop a | 15 | p.9 | |
| voltage | 208 V | p.? | |
| phase | 3 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: TLP_1112452 · extraction with per-cell provenance · verify before purchase.
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 15 |
| defrost | E |
| fan count | 2 |
| generation suffix | E |
| temp class | M |
| voltage | T3 |
Cross references
No sister-brand equivalents cataloged for this model.
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TLP215ME-T3E?
TLP215ME-T3E has a rated capacity of 14900 btu_h. See the specifications table for rating conditions.
What voltage does TLP215ME-T3E require?
TLP215ME-T3E runs on 208 V supply power.