TLP208VE-S2D

Trenton Refrigeration TLP evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
capacity8590 btu_hTLP + TLP-GEN-E p.3
8340 btu_hTLP + TLP-GEN-E p.3
8100 btu_hTLP + TLP-GEN-E p.3
7450 btu_hTLP + TLP-GEN-E p.3
6890 btu_hTLP + TLP-GEN-E p.3
8590 btu_hp.6
8340 btu_hp.6
8100 btu_hp.6
7450 btu_hp.6
6890 btu_hp.6
8020 btu_hp.7
7800 btu_hp.7
7570 btu_hp.7
6960 btu_hp.7
6430 btu_hp.7
airflow1410 cfmp.3
670 l_sp.3
1410 cfmp.4
670 l_sp.4
refrigerant charge1.4 lbsources differTLP p.3
1.5 lbsources differTLP-GEN-E p.4
(0.6) kgsources differTLP p.3
(0.7) kgsources differTLP-GEN-E p.4
1.6 lbp.6
(0.7) kgp.6
1.5 lbp.7
(0.7) kgp.7
awef rating4.01 ratiop.16
4.01 ratiop.16
4.01 ratiop.16
4.01 ratiop.24
liquid line od0.375 inchesTLP + TLP-GEN-E p.25
10 mmTLP + TLP-GEN-E p.26
suction od0.875 inchesTLP + TLP-GEN-E p.25
22 mmp.26
maximum line length 10 ft minimum room area ft224p.25
maximum line length 25 ft32TLP + TLP-GEN-E p.25
maximum line length 50 ft45TLP + TLP-GEN-E p.25
maximum line length 100 ft71TLP + TLP-GEN-E p.25
maximum line length 3m minimum room area m22p.26
maximum line length 7 6m3TLP + TLP-GEN-E p.26
maximum line length 15 2m4TLP + TLP-GEN-E p.26
maximum line length 30 5m7TLP + TLP-GEN-E p.26
fan qty2 countTLP + TLP-GEN-E p.6
motor hp0.06666666666666667 hpTLP + TLP-GEN-E p.6
motor fla1.2 ampsTLP + TLP-GEN-E p.6
total watts120 wattssources differTLP p.6
1890 wattssources differTLP p.6
1890 wattssources differTLP-GEN-E p.10
mca1.4 ampssources differTLP p.6
10.3 ampssources differTLP p.6
6.7 ampssources differTLP p.6
1.4 ampssources differTLP-GEN-E p.10
10.3 ampssources differTLP-GEN-E p.10
6.7 ampssources differTLP-GEN-E p.10
mop15 ampsTLP + TLP-GEN-E p.6
total amps8.2 ampssources differTLP p.6
5.3 ampssources differTLP p.6
8.2 ampssources differTLP-GEN-E p.10
5.3 ampssources differTLP-GEN-E p.10
defrost heaters 208 230 1 60 mop a15TLP + TLP-GEN-E p.6
defrost heaters 208 230 3 60 mop a15TLP + TLP-GEN-E p.6
voltage 208 230 1 60208-230/1/60p.33
1 x evaporator defrost kit dfk 02DFK-02p.33
1 x evaporator fuse package fp 004FP-004p.33
2 x evaporator defrost kit dfk 06DFK-06p.33
2 x evaporator fuse package fp 008FP-008p.33
voltage208 VTLP + TLP-GEN-E p.?
phase1 phTLP + TLP-GEN-E p.?
frequency60 HzTLP + TLP-GEN-E p.?
model tlpTLPp.26
TLPp.30
dimension unparsed46 1/4sources differTLP-GEN-E p.26
1175sources differTLP-GEN-E p.26
33 1/4sources differTLP-GEN-E p.26
845sources differTLP-GEN-E p.26
N/Asources differTLP-GEN-E p.26
0.625sources differTLP-GEN-E p.26
distributor inlet0.5 inchesp.26
hot gas connection0.5 inchesp.26
suction line od0.875 inchesp.39
22 mmp.40
maximum line length 10 ft minimum room area ft24p.39
maximum line length 3m minimum room area ft2p.40
unclassified partTLP part_numberp.32
motor watts120 wattsp.10
r454a sporlan ebqte aa zpEBQTE-A-ZPp.30
r448a r449a r407a r407c r454c r455a sporlan ebqve aa zpEBQVE-A-ZPp.30
r404a r507 sporlan ebqse aa zpEBQSE-A-ZPp.30

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

,

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP-GEN-E_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.

Orderable variants (1)

VariantVoltageAvailability
TLP208VE-S2D208-230/1/60Check availability

Nomenclature

Position / meaningValue
capacity code08
capacity mbh8
defrostE
fan count2
generation suffixD
temp classV
voltageS2

Parts

7 factory parts for this unit: 7from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.

PartPart numberQtyListAvailability
Distributor nozzleL1-1/2--Check availability
Electronic expansion valveE2V24order as E2V24FWBC1--Check availability
Electronic expansion valveRSV220--Check availability
Safety check valveCSOV7order as CSOV-7S--Check availability
Safety shutoff solenoidSSOV3order as SSOV3S130--Check availability
Solenoid valveB3--Check availability
Solenoid valveE3order as E3S130--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

BrandEquivalent modelBasis
KeepRiteKLP208VE-S2Dshared catalog stem
BallyBLP208VE-S2Dshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of TLP208VE-S2D?

TLP208VE-S2D has a rated capacity of 8590 btu_h. See the specifications table for rating conditions.

What voltage does TLP208VE-S2D require?

TLP208VE-S2D runs on 208 V supply power.

Related models in TLP

Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.