TLP207LE-S2E

Trenton Refrigeration TLP evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
fan qty2 countp.3
2 countTLP + TLP-GEN-E p.6
capacity7590 btu_hp.3
7370 btu_hp.3
7160 btu_hp.3
6590 btu_hp.3
6090 btu_hp.3
7590 btu_hp.5
7370 btu_hp.5
7160 btu_hp.5
6590 btu_hp.5
6090 btu_hp.5
7400 btu_hp.7
7190 btu_hp.7
6980 btu_hp.7
6420 btu_hp.7
5930 btu_hp.7
airflow1500 cfmp.3
710 l_sp.3
1500 cfmp.5
710 l_sp.5
refrigerant charge1.2 lbp.3
(0.6) kgp.3
1.2 lbp.5
(0.6) kgp.5
1.2 lbp.7
(0.6) kgp.7
awef rating3.99 ratiop.16
3.99 ratiop.16
3.99 ratiop.16
3.99 ratiop.24
liquid line od0.375 inchesTLP + TLP-GEN-E p.25
10 mmTLP + TLP-GEN-E p.26
suction od0.875 inchessources differTLP p.25
0.625 inchessources differTLP-GEN-E p.26
22 mmp.26
maximum line length 10 ft minimum room area ft220p.25
maximum line length 25 ft28TLP + TLP-GEN-E p.25
maximum line length 50 ft41TLP + TLP-GEN-E p.25
maximum line length 100 ft68TLP + TLP-GEN-E p.25
maximum line length 3m minimum room area m22p.26
maximum line length 7 6m3TLP + TLP-GEN-E p.26
maximum line length 15 2m4TLP + TLP-GEN-E p.26
maximum line length 30 5m6TLP + TLP-GEN-E p.26
motor hp0.06666666666666667 hpTLP + TLP-GEN-E p.6
motor fla1.2 ampsTLP + TLP-GEN-E p.6
total watts120 wattssources differTLP p.6
1890 wattssources differTLP p.6
1890 wattssources differTLP-GEN-E p.10
mca1.4 ampssources differTLP p.6
10.3 ampssources differTLP p.6
6.7 ampssources differTLP p.6
1.4 ampssources differTLP-GEN-E p.10
10.3 ampssources differTLP-GEN-E p.10
6.7 ampssources differTLP-GEN-E p.10
mop15 ampsTLP + TLP-GEN-E p.6
total amps8.2 ampssources differTLP p.6
5.3 ampssources differTLP p.6
8.2 ampssources differTLP-GEN-E p.10
5.3 ampssources differTLP-GEN-E p.10
defrost heaters 208 230 1 60 mop a15TLP + TLP-GEN-E p.6
defrost heaters 208 230 3 60 mop a15TLP + TLP-GEN-E p.6
esp circuit 208 230 1 60 mop a15p.9
voltage208 VTLP + TLP-GEN-E p.?
phase1 phTLP + TLP-GEN-E p.?
frequency60 HzTLP + TLP-GEN-E p.?
model tlpTLPp.26
dimension unparsed46 1/4sources differTLP-GEN-E p.26
1175sources differTLP-GEN-E p.26
33 1/4sources differTLP-GEN-E p.26
845sources differTLP-GEN-E p.26
N/Asources differTLP-GEN-E p.26
0.625sources differTLP-GEN-E p.26
distributor inlet0.5 inchesp.26
hot gas connection0.5 inchesp.26
suction line od0.875 inchesp.39
22 mmp.40
maximum line length 10 ft minimum room area ft20p.39
maximum line length 3m minimum room area ft2p.40
unclassified partTLP part_numberp.31
motor watts120 wattsp.10
esp circuit mca10.3 ampsp.13
esp 208 230 1 60 mop a15p.13
voltage 208 230 1 60208-230/1/60p.47

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

,

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including TLP-GEN-E_1112452, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.

Orderable variants (1)

VariantVoltageAvailability
TLP207LE-S2E208-230/1/60Check availability

Nomenclature

Position / meaningValue
capacity code07
capacity mbh7
defrostE
fan count2
generation suffixE
temp classL
voltageS2

Parts

6 factory parts for this unit: 6from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.

PartPart numberQtyListAvailability
Distributor nozzleL1--Check availability
Electronic expansion valveE2V24order as E2V24FWBC1--Check availability
Electronic expansion valveRSV220--Check availability
Safety check valveCSOV7order as CSOV-7S--Check availability
Safety shutoff solenoidSSOV3order as SSOV3S130--Check availability
Solenoid valveE3order as E3S130--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

BrandEquivalent modelBasis
KeepRiteKLP207LE-S2Eshared catalog stem
BallyBLP207LE-S2Eshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of TLP207LE-S2E?

TLP207LE-S2E has a rated capacity of 7590 btu_h. See the specifications table for rating conditions.

What voltage does TLP207LE-S2E require?

TLP207LE-S2E runs on 208 V supply power.

Related models in TLP

Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.