THP190VE-T4E

Trenton Refrigeration THP evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
capacity201400 btu_hTHP + THP-GEN-E p.6
195700 btu_hTHP + THP-GEN-E p.6
190000 btu_hTHP + THP-GEN-E p.6
172900 btu_hTHP + THP-GEN-E p.6
161500 btu_hTHP + THP-GEN-E p.6
163800 btu_hp.6
159100 btu_hp.6
154500 btu_hp.6
140600 btu_hp.6
131300 btu_hp.6
201400 btu_hTHP + THP-GEN-E p.6
195700 btu_hTHP + THP-GEN-E p.6
190000 btu_hTHP + THP-GEN-E p.6
172900 btu_hTHP + THP-GEN-E p.6
161500 btu_hTHP + THP-GEN-E p.6
163800 btu_hp.8
159100 btu_hp.8
154500 btu_hp.8
140600 btu_hp.8
131300 btu_hp.8
airflow23500 cfmTHP + THP-GEN-E p.6
11090 l_sTHP + THP-GEN-E p.6
refrigerant charge62.4 lbp.6
28.3 kgp.6
57.4 lbp.6
26.1 kgp.6
40.1 lbsources differTHP p.6
40.2 lbsources differTHP-GEN-E p.4
18.2 kgTHP + THP-GEN-E p.6
59.9 lbp.6
27.2 kgp.6
62.4 lbp.6
28.3 kgp.6
57.4 lbp.8
26.1 kgp.8
awef rating4.15 ratiop.28
4.15 ratiop.28
4.15 ratiop.28
4.15 ratiop.28
4.15 ratiop.28
4.15 ratiop.28
4.15 ratiop.31
4.15 ratiop.31
suction od3-1/8 inchessources differTHP p.31
3 7/8 inchessources differTHP-GEN-E p.36
distributor inlet1 5/8 inchesp.31
1 5/8 inchesTHP + THP-GEN-E p.31
side port connection1-5/8 inchesp.31
1-5/8 inchesp.36
hot gas connection1-5/8 inchesp.31
shipping weight1204 lbp.32
546 kgp.32
mca75.4 ampssources differTHP p.14
15 ampssources differTHP-GEN-E p.11
37.7 ampssources differTHP-GEN-E p.11
esp circuit 460 3 60 mop a80THP + THP-GEN-E p.14
voltage460 VTHP + THP-GEN-E p.?
phase3 phTHP + THP-GEN-E p.?
frequency60 HzTHP + THP-GEN-E p.?
fan qty4 countp.36
drain pan loop conn od sweat 1 3 81-5/8p.36
r454a sporlan ebste 8 zpOTE-40-ZPp.40
r448a r449a r407a r407c r454c r455a sporlan ebsve 8 zpOVE-40-ZPp.40
r404a r507 sporlan ebsse 7 1 2 zpOSE-35-ZPp.40
liquid line od1 1/8 inchesp.49
29 mmp.50
suction line od3 1/8 inchesp.49
79 mmp.50
maximum line length a 10 ft minimum room area ft2545*p.49
maximum line length b 25 ft629*p.49
maximum line length c 50 ft769*p.49
maximum line length d 100 ft1048*p.49
maximum line length a 3m minimum room area m251*p.50
maximum line length b 7 6m58*p.50
maximum line length c 15 2m71*p.50
maximum line length d 30 5m97*p.50
motor hp1 hpp.11
motor fla10 ampsp.11
motor watts2080 wattsp.11
mop20 ampsp.11
total watts45500 wattsp.11
total amps30.1 ampsp.11
defrost heaters circuit 1 460 3 60 mop a40p.11
defrost heaters circuit 2 460 3 60 mop a40p.11
esp circuit mca75.4 ampsp.16
of fans 14p.58

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including THP_1111525, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

,

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including THP-GEN-E_1112936, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.

Orderable variants (1)

VariantVoltageAvailability
THP190VE-T4E460/3/60Check availability

Nomenclature

Position / meaningValue
capacity code190
capacity mbh190
defrostE
generation suffixE
temp classV
voltageT4

Parts

5 factory parts for this unit: 5from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

PartPart numberQtyListAvailability
Distributor nozzleA40--Check availability
Electronic expansion valveE3V65order as E3V65BWRC1--Check availability
Safety check valveCSOV25--Check availability
Safety shutoff solenoidSSOV25--Check availability
Solenoid valveB19order as B19S2-7/8--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

BrandEquivalent modelBasis
KeepRiteKHP190VE-T4Eshared catalog stem
BallyBHP190VE-T4Eshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of THP190VE-T4E?

THP190VE-T4E has a rated capacity of 201400 btu_h. See the specifications table for rating conditions.

What voltage does THP190VE-T4E require?

THP190VE-T4E runs on 460 V supply power.

Related models in THP

Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.