Trenton Refrigeration · THP · High Profile Evaporators

THP143ME-T4D

Trenton Refrigeration THP high profile evaporator.

64 extracted specifications, each traceable to its source document and page.

Specifications

SpecificationValueSource
fan qty3 countp.4
3 countp.4
3 countp.4
3 countp.31
3 countp.31
3 countp.9
capacity143200 btu_hp.4
141800 btu_hp.4
140300 btu_hp.4
116400 btu_hp.4
115200 btu_hp.4
114100 btu_hp.4
143200 btu_hp.4
141800 btu_hp.4
140300 btu_hp.4
airflow18600 cfmp.4
8780 l_sp.4
18600 cfmp.4
8780 l_sp.4
18600 cfmp.4
8780 l_sp.4
refrigerant charge26.4 lbp.4
12 kgp.4
24.3 lbp.4
11 kgp.4
19.3 lbp.4
8.7 kgp.4
r404a r5079p.28
r448a r449a9p.28
r407c r407a9p.28
awef rating9 ratiop.28
9 ratiop.28
9 ratiop.28
suction od2-1/8 inchesp.31
2-1/8 inchesp.31
distributor inlet1 5/8 inchesp.31
1 5/8 inchesp.31
reverse cycle 3 pipe defrost side port connection od sweat1-3/8p.31
hot gas connection1-5/8 inchesp.31
distributor nozzleA17 part_idp.33
A17 part_idp.34
electronic expansion valveE3V65 part_numberp.34
solenoid valveB14 part_numberp.34
safety solenoid valveSSOV19 part_numberp.34
safety check valveCSOV17 part_numberp.34
shipping weight845 lbp.32
383 kgp.32
motor hp1 hpp.9
motor fla7.5 ampsp.9
total watts1560 wattsp.9
24500 wattsp.9
mca15 ampsp.9
41.5 ampsp.9
- ampsp.9
41.5 ampsp.14
fan motors standard ec motors mop a20p.9
total amps33.2 ampsp.9
- ampsp.9
defrost heaters 460 3 60 circuit 1 mop a45p.9
defrost heaters 460 3 60 circut 2 mop a-p.9
esp circuit 460 3 60 mop a45p.14
voltage460 Vp.?
phase3 php.?
frequency60 Hzp.?

Sources: THP_1111525 · extraction with per-cell provenance · verify before purchase. · variants from distributor API snapshot

Orderable variants (1)

VariantVoltageAvailability
THP143ME-T4D460/3/60Check availability

Nomenclature

Position / meaningValue
capacity code43
defrostE
fan count1
generation suffixD
temp classM
voltageT4

Cross references

BrandEquivalent modelBasis
KeepRiteKHP143ME-T4Dshared catalog stem
BallyBHP143ME-T4Dshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of THP143ME-T4D?

THP143ME-T4D has a rated capacity of 143200 btu_h. See the specifications table for rating conditions.

What voltage does THP143ME-T4D require?

THP143ME-T4D runs on 460 V supply power.

Related models in THP