THP095MH-S2D

Trenton Refrigeration THP high profile evaporator.

Specifications

Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.

SpecificationValueSource
fan qty2 countp.4
capacity95300 btu_hp.4
94300 btu_hp.4
93400 btu_hp.4
77500 btu_hp.4
76700 btu_hp.4
76000 btu_hp.4
95300 btu_hp.4
94300 btu_hp.4
93400 btu_hp.4
airflow12400 cfmp.4
5850 l_sp.4
refrigerant charge17.8 lbp.4
8.1 kgp.4
16.4 lbp.4
7.4 kgp.4
13 lbp.4
5.9 kgp.4
17.1 lbp.4
7.8 kgp.4
awef rating9 ratiop.28
9 ratiop.28
9 ratiop.28
9 ratiop.28
9 ratiop.28
9 ratiop.28
suction od1-5/8 inchesp.31
distributor inlet1 3/8 inchesp.31
1 3/8 inchesp.31
side port connection1-1/8 inchesp.31
hot gas connection1-3/8 inchessources differTHP p.31
095MR inchessources differTHP p.32
286 inchessources differTHP p.32
631 lbp.32
motor hp095MG hpsources differTHP p.32
095MT hpsources differTHP p.32
1 hpsources differTHP p.12
shipping weight601 lbp.32
272 kgp.32
motor fla10 ampsp.12
total watts1120 wattsp.12
mca15 ampsp.12
mop20 ampsp.12
voltage208 Vp.?
phase1 php.?
frequency60 Hzp.?

Sources:

Source documents

Every value on this page is cited to a manufacturer document. Direct links to the documents, including THP_1111525, are a free member benefit. Accounts are coming; leave an email and we'll be in touch when source access goes live.

. Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.

Orderable variants (1)

VariantVoltageAvailability
THP095MH-S2D208-230/1/60Check availability

Nomenclature

Position / meaningValue
capacity code095
capacity mbh95
defrostH
generation suffixD
temp classM
voltageS2

Parts

5 factory parts for this unit: 5from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.

Expansion and refrigerant circuit

PartPart numberQtyListAvailability
Distributor nozzleC12--Check availability
Electronic expansion valveE3V55order as E3V55BWRC1--Check availability
Safety check valveCSOV13order as CSOV-13S--Check availability
Safety shutoff solenoidSSOV19--Check availability
Solenoid valveB10order as B10S2-5/8--Check availability

Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.

Cross references

BrandEquivalent modelBasis
KeepRiteKHP095MH-S2Dshared catalog stem
BallyBHP095MH-S2Dshared catalog stem

In progress: cross-brand replacements by specification matching.

Frequently asked questions

What is the capacity of THP095MH-S2D?

THP095MH-S2D has a rated capacity of 95300 btu_h. See the specifications table for rating conditions.

What voltage does THP095MH-S2D require?

THP095MH-S2D runs on 208 V supply power.

Related models in THP

Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.