THP062CG-T3D
Trenton Refrigeration THP high profile evaporator.
Specifications
Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.
| Specification | Value | Conditions | Source |
|---|---|---|---|
| capacity | 50400 btu_h | evap temp f: 25; refrigerant: CO2 | p.36 |
| 49900 btu_h | evap temp f: 15; refrigerant: CO2 | p.36 | |
| 49400 btu_h | evap temp f: 10; refrigerant: CO2 | p.36 | |
| airflow | 5700 cfm | p.36 | |
| 2690 l_s | p.36 | ||
| refrigerant charge | 11.4 lb | refrigerant: CO2 | p.36 |
| 5.2 kg | refrigerant: CO2 | p.36 | |
| awef rating | 9 ratio | refrigerant: CO2 | p.41 ✓ |
| suction od | 0.625 inches | p.44 | |
| distributor inlet | 0.625 inches | p.44 | |
| 0.625 inches | defrost piping: reverse_cycle | p.45 | |
| liquid line od | 0.5 inches | p.44 | |
| 0.5 inches | defrost piping: reverse_cycle | p.45 | |
| side port connection | 0.5 inches | p.45 | |
| hot gas connection | 0.625 inches | p.45 | |
| fan qty | 1 count | p.39 ✓ | |
| motor hp | 1 hp | p.39 | |
| motor fla | 5 amps | p.39 | |
| total watts | 560 wattssources differ | THP p.39 | |
| 3780 wattssources differ | THP p.39 | ||
| mca | 15 ampssources differ | THP p.39 | |
| 11.9 ampssources differ | THP p.39 | ||
| mop | 20 amps | p.39 | |
| total amps | 9.5 amps | p.39 | |
| drain pan heaters 208 230 3 60 2 spd ecm std mop a | 15 | p.39 | |
| voltage | 208 V | p.? | |
| phase | 3 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: . Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.
Orderable variants (1)
| Variant | Voltage | Availability |
|---|---|---|
| THP062CG-T3D | 208-230/3/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 062 |
| capacity mbh | 62 |
| defrost | G |
| generation suffix | D |
| temp class | C |
| voltage | T3 |
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KHP062CG-T3D | shared catalog stem ✓ |
| Bally | BHP062CG-T3D | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of THP062CG-T3D?
THP062CG-T3D has a rated capacity of 50400 btu_h. See the specifications table for rating conditions.
What voltage does THP062CG-T3D require?
THP062CG-T3D runs on 208 V supply power.
Related models in THP
Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.