Trenton Refrigeration · TEP · Extended Profile Evaporators- A2L For "E" Generation
TEP060DR-S4D
Trenton Refrigeration TEP extended profile s- a2l for "e" generation evaporator.
31 extracted specifications, each traceable to its source document and page.
Specifications
| Specification | Value | Conditions | Source |
|---|---|---|---|
| fan qty | 2 count | p.42 | |
| 2 count | p.43 | ||
| capacity | 51300 btu_h | evap temp f: 0 | p.42 |
| 49900 btu_h | evap temp f: 10 | p.42 | |
| 48400 btu_h | evap temp f: 20 | p.42 | |
| 44500 btu_h | evap temp f: 30 | p.42 | |
| 41100 btu_h | evap temp f: 40 | p.42 | |
| airflow | 6900 cfm | p.42 | |
| 3260 l_s | p.42 | ||
| refrigerant charge | 11.9 lb | p.42 | |
| 5.4 kg | p.42 | ||
| awef rating | 4.15 ratio | refrigerant: CO2 | p.47 |
| suction od | 0.875 inches | p.49 | |
| distributor inlet | 0.875 inches | p.49 | |
| reverse cycle 3 pipe defrost side port connection od sweat | 0.5 | p.49 | |
| hot gas connection | 0.5 inches | p.49 | |
| 355 lb | p.50 | ||
| 161 inches | p.50 | ||
| distributor nozzle | J2 part_id | p.50 | |
| nozle hg | G2 | p.50 | |
| with electric heater pan model tep | 060DG | p.50 | |
| shipping weight | 340 lb | p.50 | |
| 154 kg | p.50 | ||
| motor fla | 1 amps | p.43 | |
| 5 amps | p.43 | ||
| 700 amps | p.43 | ||
| mca | 15 amps | p.43 | |
| 20 amps | p.43 | ||
| voltage | 460 V | p.? | |
| phase | 1 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: TEP_1109296 · extraction with per-cell provenance · verify before purchase. · variants from distributor API snapshot
Orderable variants (1)
| Variant | Voltage | Availability |
|---|---|---|
| TEP060DR-S4D | 460/1/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 60 |
| defrost | R |
| fan count | 0 |
| generation suffix | D |
| temp class | D |
| voltage | S4 |
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KEP060DR-S4D | shared catalog stem ✓ |
| Bally | BEP060DR-S4D | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TEP060DR-S4D?
TEP060DR-S4D has a rated capacity of 51300 btu_h. See the specifications table for rating conditions.
What voltage does TEP060DR-S4D require?
TEP060DR-S4D runs on 460 V supply power.
Related models in TEP
Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.