TEP050DE-S2D
Trenton Refrigeration TEP extended profile evaporators- a2l for "e" generation evaporator.
Specifications
Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.
| Specification | Value | Conditions | Source |
|---|---|---|---|
| fan qty | 2 count | p.42 ✓ | |
| capacity | 43400 btu_h | evap temp f: 0; refrigerant: CO2 | p.42 |
| 42100 btu_h | evap temp f: 10; refrigerant: CO2 | p.42 | |
| 40900 btu_h | evap temp f: 20; refrigerant: CO2 | p.42 | |
| 37600 btu_h | evap temp f: 30; refrigerant: CO2 | p.42 ✓ | |
| 34800 btu_h | evap temp f: 40; refrigerant: CO2 | p.42 | |
| airflow | 7300 cfm | p.42 | |
| 3450 l_s | p.42 | ||
| refrigerant charge | 8.9 lb | refrigerant: CO2 | p.42 |
| 4 kg | refrigerant: CO2 | p.42 | |
| awef rating | 4.15 ratio | refrigerant: CO2 | p.47 ✓ |
| suction od | 0.625 inches | p.49 | |
| distributor inlet | 0.5 inches | defrost piping: reverse_cycle_3_pipe | p.49 |
| 0.625 inches | p.49 | ||
| side port connection | 0.5 inches | defrost piping: reverse_cycle_3_pipe | p.49 |
| hot gas connection | 0.5 inches | p.49 | |
| nozle hg | J1-1/2 | p.50 | |
| liquid line od | 0.375 inches | p.49 | |
| shipping weight | 335 lb | p.50 | |
| 152 kg | p.50 | ||
| motor hp | 0.5 hp | p.44 ✓ | |
| motor fla | 8.4 amps | p.44 | |
| total watts | 700 wattssources differ | TEP p.44 | |
| 8837 wattssources differ | TEP p.44 | ||
| NA wattssources differ | TEP p.44 | ||
| mca | 15 ampssources differ | TEP p.44 | |
| 48 ampssources differ | TEP p.44 | ||
| NA ampssources differ | TEP p.44 | ||
| mop | 20 amps | p.44 | |
| total amps | 38.4 ampssources differ | TEP p.44 | |
| NA ampssources differ | TEP p.44 | ||
| defrost heaters 208 230 1 60 circuit 1 mop a | 50 | p.44 | |
| defrost heaters 208 230 1 60 circuit 2 mop a | NA | p.44 | |
| voltage | 208 V | p.? | |
| phase | 1 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: . Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.
Orderable variants (1)
| Variant | Voltage | Availability |
|---|---|---|
| TEP050DE-S2D | 208-230/1/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 050 |
| capacity mbh | 50 |
| defrost | E |
| generation suffix | D |
| temp class | D |
| voltage | S2 |
Parts
1 factory parts for this unit: 1from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.
Expansion and refrigerant circuit
| Part | Part number | Description | Qty | List | Availability |
|---|---|---|---|---|---|
| Distributor nozzle | J1-1/2✓ | Distributor nozzle, Sporlan (Parker Hannifin) | - | - | Check availability |
Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KEP050DE-S2D | shared catalog stem ✓ |
| Bally | BEP050DE-S2D | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TEP050DE-S2D?
TEP050DE-S2D has a rated capacity of 43400 btu_h. See the specifications table for rating conditions.
What voltage does TEP050DE-S2D require?
TEP050DE-S2D runs on 208 V supply power.
Related models in TEP
Independent reference. Not affiliated with any manufacturer. Verify specifications against manufacturer documentation before purchase.