TEP036HA-S2D
Trenton Refrigeration TEP extended profile evaporators- a2l for "e" generation evaporator.
Specifications
Note:for some values below, the manufacturer's own documents disagree. Both figures are shown with their source. CrossRefHVAC is confirming the correct values with the manufacturer.
| Specification | Value | Conditions | Source |
|---|---|---|---|
| capacity | 36200 btu_h | evap temp f: 25; refrigerant: R407A/R407C/R448A/R449A | p.3 |
| 35800 btu_h | evap temp f: 15; refrigerant: R407A/R407C/R448A/R449A | p.3 | |
| 35500 btu_h | evap temp f: 10; refrigerant: R407A/R407C/R448A/R449A | p.3 | |
| 29400 btu_h | evap temp f: 25; refrigerant: R404A/R507 | p.3 | |
| 29100 btu_h | evap temp f: 15; refrigerant: R404A/R507 | p.3 | |
| 28800 btu_h | evap temp f: 10; refrigerant: R404A/R507 | p.3 | |
| 36200 btu_h | evap temp f: 25; refrigerant: R454A/R454C/R455A | p.3 | |
| 35800 btu_h | evap temp f: 15; refrigerant: R454A/R454C/R455A | p.3 | |
| 35500 btu_h | evap temp f: 10; refrigerant: R454A/R454C/R455A | p.3 | |
| airflow | 3500 cfm | p.3 | |
| 1650 l_s | p.3 | ||
| refrigerant charge | 6.7 lb | refrigerant: R407A/R407C | p.3 |
| 3 kg | refrigerant: R407A/R407C | p.3 | |
| 6.4 lb | refrigerant: R404A/R507 | p.3 | |
| 2.9 kg | refrigerant: R404A/R507 | p.3 | |
| 6.1 lb | refrigerant: R454A/R454C/R455A | p.3 | |
| 2.8 kg | refrigerant: R454A/R454C/R455A | p.3 | |
| 6.4 lb | refrigerant: R448A/R449A | p.3 | |
| 2.9 kg | refrigerant: R448A/R449A | p.3 | |
| awef rating | 9 ratio | refrigerant: R404A/R507 | p.35 ✓ |
| 9 ratio | refrigerant: R407A/R407C | p.35 | |
| 9 ratio | refrigerant: R448A/R449A | p.35 | |
| 9 ratio | refrigerant: R454A | p.35 | |
| 9 ratio | refrigerant: R454C | p.35 | |
| 9 ratio | refrigerant: R455A | p.35 | |
| suction od | 1 1/8 inches | p.37 | |
| distributor inlet | 0.875 inches | p.37 | |
| shipping weight | 210 lb | p.38 | |
| 95 kg | p.38 | ||
| fan qty | 1 count | p.7 ✓ | |
| motor fla | 0.5 ampssources differ | TEP p.7 | |
| 4.2 ampssources differ | TEP p.7 | ||
| 350 ampssources differ | TEP p.7 | ||
| mca | 15 ampssources differ | TEP p.7 | |
| 20 ampssources differ | TEP p.7 | ||
| voltage | 208 V | p.? | |
| phase | 1 ph | p.? | |
| frequency | 60 Hz | p.? |
Sources: . Extraction with per-cell provenance. Verify before purchase. Variants from distributor API snapshot.
Orderable variants (1)
| Variant | Voltage | Availability |
|---|---|---|
| TEP036HA-S2D | 208-230/1/60 | Check availability |
Nomenclature
| Position / meaning | Value |
|---|---|
| capacity code | 036 |
| capacity mbh | 36 |
| defrost | A |
| generation suffix | D |
| temp class | H |
| voltage | S2 |
Parts
7 factory parts for this unit: 7from the manufacturer's selection documents, 0 from Trenton service parts records. Prices are manufacturer list.
Expansion and refrigerant circuit
Where several valves of one kind are listed, they are the manufacturer's selection options: which one a unit carries depends on the operating conditions shown. The service parts rows show what a documented build was actually fitted with.
| Part | Part number | Description | Qty | List | Availability |
|---|---|---|---|---|---|
| Distributor nozzle | G4✓ | Distributor nozzle; Distributor nozzle, Sporlan (Parker Hannifin) | - | - | Check availability |
| Electronic expansion valve | E2V35order as E2V35FSMC0✓ | Electronic expansion valve (EEV), Carel | - | - | Check availability |
| Safety check valve | CSOV9order as CSOV-9S✓ | Safety check valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Safety shutoff solenoid | SSOV10✓ | Safety shutoff solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| Solenoid valve | B6order as B6S1✓ | Solenoid valve, Sporlan (Parker Hannifin) | - | - | Check availability |
| TXV | ERSE-4-C✓ | refrigerant: R404A/R507 | - | - | Check availability |
| TXV | ERVE-5-C✓ | refrigerant: R407A/R407C/R448A/R449A | - | - | Check availability |
Sources: manufacturer selection documents (page-cited) and Trenton service parts records. NLA: no longer available from the manufacturer. Verify before purchase.
Cross references
| Brand | Equivalent model | Basis |
|---|---|---|
| KeepRite | KEP036HA-S2D | shared catalog stem ✓ |
| Bally | BEP036HA-S2D | shared catalog stem ✓ |
In progress: cross-brand replacements by specification matching.
Frequently asked questions
What is the capacity of TEP036HA-S2D?
TEP036HA-S2D has a rated capacity of 36200 btu_h. See the specifications table for rating conditions.
What voltage does TEP036HA-S2D require?
TEP036HA-S2D runs on 208 V supply power.
Related models in TEP